Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 6
items per page: 25 50 75
Sort by:

Abstract

The article discusses changes in Polish regulations concerning assessment of the climate hazard in underground mines. Currently, the main empirical index representing the heat strain, used in qualification of the workplace to one of the climate hazard levels in Poland is the equivalent climate temperature. This simple heat index allows easy and quick assessment of the climate hazard. To a major extent, simple heat indices have simplifications and are developed for a specific working environments. Currently, the best methods used in evaluation of microclimate conditions in the workplace are those based on the theory of human thermal balance, where the physiological parameters characterising heat strain are body water loss and internal core temperature of the human body. The article describes the results of research on usage of equivalent climate temperature to heat strain evaluation in underground mining excavations. For this purpose, the numerical model of heat exchange between man and his environment was used, taken from PN-EN ISO 7933:2005. The research discussed in this paper has been carried out considering working conditions and clothing insulation in use in underground mines. The analyses performed in the study allowed formulation of conclusions concerning application of the equivalent climate temperature as a criterion of assessment of climate hazards in underground mines.
Go to article

Abstract

An original fuzzy team control model is presented in this article. The model is based on a non-traditional combination of classical and contemporary achievements of management and mathematical theories of fuzzy logic and fuzzy sets. In methodological terms, the article also offers a set of tools for measuring and evaluating both team performance and the effectiveness of the team control system in the organization. Fuzzy tools and techniques for decision-making, studying of hidden effects and joint influences, and quantification of evaluations are employed in this set of tools. The suggested fuzzy model contributes to overcoming theoretical deficits on the issues of team control, and the methodology of team control fills a gap in the toolkit of team management. The results from verification of the fuzzy team control model at a small-sized Bulgarian enterprise are also discussed in this article. They indicate that it is possible to develop a fuzzy model for team control, increasing the effectiveness of the team control system in the enterprise.
Go to article

Abstract

This paper constitutes the sensitivity study of application the Polar WRF model to the Svalbard area with testing selected parameterizations, including planetary boundary layer, radiation and microphysics schemes. The model was configured, using three one-way nested domains with 27 km, 9 km and 3 km grid cell resolutions. Results from the innermost domain were presented and compared against measured wind speed and air temperature at 10 meteorological stations. The study period covers two months: June 2008 and January 2009. Significant differences between simulations results occurred for planetary boundary layer (PBL) schemes in January 2009. The Mellor-Yamada-Janjic (MYJ) planetary boundary layer (PBL) scheme resulted in the lowest errors for air temperature, according to mean error (ME), mean absolute error (MAE) and correlation coefficient values, where for wind speed this scheme was the worst from all the PBL schemes tested. In the case of June 2008, shortwave and longwave radiation schemes influenced the results the most. Generally, higher correlations were obtained for January, both for air temperature and wind speed. However, the model performs better for June in terms of ME and MAE error statistics. The results were also analyzed spatially, to summarize the uncertainty of the model results related to the analyzed parameterization schemes groups. Significant variability among simulations was calculated for January 2009 over the northern part of Spitsbergen and fjords for the PBL schemes. Standard deviations for monthly average simulated values were up to 3.5°C for air temperature and around 1 m s-1 for wind speed.
Go to article

Abstract

An evaluation method is developed for temperature oscillation experiments in heat exchangers. The unity Mach number dispersion model is applied. For the consideration of lateral wall heat conduction an effective wall thickness is introduced together with a wall heat transfer coefficient. The evaluation method may also be applied to single blow experiments with pulse signals. A sensitivity analysis describes and discusses the accuracy of different evaluation procedures.
Go to article

Abstract

An evaluation method is developed for single blow experiments with liquids on heat exchangers. The method is based on the unity Mach number dispersion model. The evaluation of one experiment yields merely one equation for the two unknowns, the number of transfer units and the dispersive Peclet number. Calculations on an example confirm that one single blow test alone cannot provide reliable values of the unknowns. A second test with a liquid of differing heat capacity is required, or a tracer experiment for the measurement of the Peclet number. A modified method is developed for gases. One experiment yields the effective number of transfer units and approximate values of the two unknowns. The numerical evaluation of calculated experiments demonstrates the applicability of the evaluation methods.
Go to article

Abstract

The recently developed special unity Mach number dispersion model prescribes the corrections to heat transfer coefficients which are simple functions of the dispersive Peclet numbers. They can be determined through the residence time measurements. An evaluation method is described in which the measured input and response concentration profiles are numerically Laplace transformed and evaluated in the frequency domain. A characteristic mean Peclet number is defined. The method is also applied to the parabolic dispersion model and the cascade model. A calculated example of a tube bundle with maldistribution and backflow demonstrates the suitability of the evaluation method.
Go to article

This page uses 'cookies'. Learn more