Search results

Filters

  • Journals
  • Date

Search results

Number of results: 6
items per page: 25 50 75
Sort by:

Abstract

In this work we report simulation and experimental results for an MWIR HgCdTe photodetector designed by computer simulation and fabricated in a joint laboratory run by VIGO Sytems S.A. and Military University of Technology. The device is based on a modified N+pP+ heterostructure grown on 2”., epiready, semi-insulating (100) GaAs substrates in a horizontal MOCVD AIX 200 reactor. The devices were examined by measurements of spectral and time responses as a function of a bias voltage and operating temperatures. The time response was measured with an Optical Parametric Oscillator (OPO) as the source of ~25 ps pulses of infrared radiation, tuneable in a 1.55–16 μm spectral range. Two-stage Peltier cooled devices (230 K) with a 4.1 μm cut-off wavelength were characterized by 1.6 × 1012 cm Hz1/2/W peak detectivity and < 1 ns time constant for V > 500 mV.
Go to article

Abstract

Decisions involving comparisons of Arabic number digits often exhibit an interference between the physical size of the digit and the implied numerical magnitude, a phenomenon called the size-congruity effect. Related research over the past four decades has yielded two competing models of the phenomenon: an early interaction account, where interference between numerical and physical magnitude occurs at an early encoding stage, and a late interaction account, where the interference occurs downstream as response competition during the decision process. In the present study, we asked participants to compare the physical sizes of pairs of Arabic digits. We fit the resulting response time distributions with a shifted Wald model, a single boundary accumulator model, which gave us estimates of information accumulation rate (drift rate), response threshold, and nondecision time. We found that incongruity between physical size and numerical magnitude affected the decision-related estimates of drift rate and response threshold. Further, a Bayesian analysis confirmed a null effect of congruity on nondecision time. These results indicate that the observed interference originates from decision-related processes, lending further support for a late interaction account of the size-congruity effect.
Go to article

Abstract

The paper reports on a long-wave infrared (cut-off wavelength ~ 9 μm) HgCdTe detector operating under nbiased condition and room temperature (300 K) for both short response time and high detectivity operation. The ptimal structure in terms of the response time and detectivity versus device architecture was shown. The response time of the long-wave (active layer Cd composition, xCd = 0.19) HgCdTe detector for 300 K was calculated at a level of τs ~ 1 ns for zero bias condition, while the detectivity − at a level of D* ~ 109 cmHz1/2/W assuming immersion. It was presented that parameters of the active layer and P+ barrier layer play a critical role in order to reach τs ≤ 1 ns. An extra series resistance related to the processing (RS+ in a range 5−10 Ω) increased the response time more than two times (τs ~ 2.3 ns).
Go to article

Abstract

The dual core bit-byte CPU must be equipped with properly designed circuits, providing interface between the two processor units, and making it possible to exploit all its advantages like versatility of the byte unit and speed of the bit unit. First of all, the interface circuits should be designed in such a way, that they don’t disturb maximally parallel operation of the units, and that the CPU as a whole works in the same manner as in a standard PLC. The paper presents hardware solutions supporting effective operation of PLC CPU-s. Possibilities of solving problems concerning data exchange between a CPU and peripheral circuits were presented, with a special stress on timers and counters, and also on data exchange between the bit unit and the byte unit. The objective of the proposed solutions is to decrease the time necessary for a CPU to access its peripheries.
Go to article

Abstract

In virtual acoustics or artificial reverberation, impulse responses can be split so that direct and reflected components of the sound field are reproduced via separate loudspeakers. The authors had investigated the perceptual effect of angular separation of those components in commonly used 5.0 and 7.0 multichannel systems, with one and three sound sources respectively (Kleczkowski et al., 2015, J. Audio Eng. Soc. 63, 428-443). In that work, each of the front channels of the 7.0 system was fed with only one sound source. In this work a similar experiment is reported, but with phantom sound sources between the front loud- speakers. The perceptual advantage of separation was found to be more consistent than in the condition of discrete sound sources. The results were analysed both for pooled listeners and in three groups, according to experience. The advantage of separation was the highest in the group of experienced listeners.
Go to article