Search results

Filters

  • Journals
  • Date

Search results

Number of results: 14
items per page: 25 50 75
Sort by:

Abstract

It is possible to enhance acoustic isolation of the device from the environment by appropriately controlling vibration of a device casing. Sound insulation efficiency of this technique for a rigid casing was confirmed by the authors in previous publications. In this paper, a light-weight casing is investigated, where vibrational couplings between walls are much greater due to lack of a rigid frame. A laboratory setup is described in details. The influence of the cross-paths on successful global noise reduction is considered. Multiple vibration actuators are installed on each of the casing walls. An adaptive control strategy based on the Least Mean Square (LMS) algorithm is used to update control filter parameters. Obtained results are reported, discussed, and conclusions for future research are drawn.
Go to article

Abstract

The active noise-reducing casing developed and promoted by the authors in recent publications have multiple advantages over other active noise control methods. When compared to classical solutions, it allows for obtaining global reduction of noise generated by a device enclosed in the casing. Moreover, the system does not require loudspeakers, and much smaller actuators attached to the casing walls are used instead. In turn, when compared to passive casings, the walls can be made thinner, lighter and with much better thermal transfer than sound-absorbing materials. For active noise control a feedforward structure is usually used. However, it requires an in-advance reference signal, which can be difficult to be acquired for some applications. Fortunately, usually the dominant noise components are due to rotational operations of the enclosed device parts, and thus they are tonal and multitonal. Therefore, it can be adequately predicted and the Internal Model Control structure can be used to benefit from algorithms well developed for feedforward systems. The authors have already tested that approach for a rigid casing, where interaction of the walls was significantly reduced. In this paper the idea is further explored and applied for a light-weight casing, more frequently met in practice, where each vibrating wall of the casing influences all the other walls. The system is verified in laboratory experiments.
Go to article

Abstract

There are many industrial environments which are exposed to a high-level noise. It is necessary to protect people from the noise. Most of the time, the consumer requires a miniature version of a noise canceller to satisfy the internal working place requirements. Very important thing is to select the most appropriate personal hearing protection device, for example an earplug. It should guarantee high passive noise attenuation and allow for secondary sound generation in case of active control. In many cases the noise is nonstationary. For instance, some of the noisy devices are switched on and off, speed of some rotors or fans changes, etc. To avoid any severe transient acoustic effects due to potential convergence problems of adaptive systems, a fixed-parameter approach to control is appreciated. If the noise were stationary, it would be possible to design an optimal control filter minimising variance of the signal being the effect of the acoustic noise and the secondary sound interference. Because of noise nonstationarity for most applications, the idea of generalised disturbance defined by a frequency window of different types has been developed by the authors and announced in previous publications. The aim of this paper is to apply such an approach to different earplugs and verify its noise reduction properties. Simulation experiments are conducted based on real world measurements performed using the G. R. A. S. artificial head equipped with an artificial mechanical ear, and the noise recorded in a power plant.
Go to article

Abstract

Vibrating plates can be used in Active Noise Control (ANC) applications as active barriers or as secondary sources replacing classical loudspeakers. The system with vibrating plates, especially when nonlinear MFC actuators are used, is nonlinear. The nonlinearity in the system reduces performance of classical feedforward ANC with linear control filters systems, because they cannot cope with harmonics generated by the nonlinearity. The performance of the ANC system can be improved by using nonlinear control filters, such as Artificial Neural Networks or Volterra filters. However, when multiple actuators are mounted on a single plate, which is a common practice to provide effective control of more vibration modes, each actuator should be driven by a dedicated nonlinear control filter. This significantly increases computational complexity of the control algorithm, because adaptation of nonlinear control filters is much more computationally demanding than adaptation of linear FIR filters. This paper presents an ANC system with multiple actuators, which are driven with a single nonlinear filter. To avoid destructive interference of vibrations generated by different actuators the control signal is filtered by appropriate separate linear filters. The control system is experimentally verified and obtained results are reported.
Go to article

Abstract

Noise control has gained a lot of attention recently. However, presence of nonlinearities in signal paths for some applications can cause significant difficulties in the operation of control algorithms. In particular, this problem is common in structural noise control, which uses a piezoelectric shunt circuit. Not only vibrating structures may exhibit nonlinear characteristics, but also piezoelectric actuators. In this paper, active device casing is addressed. The objective is to minimize the noise coming out of the casing, by controlling vibration of its walls. The shunt technology is applied. The proposed control algorithm is based on algorithms from a group of soft computing. It is verified by means of simulations using data acquired from a real object.
Go to article

Abstract

Vibrating plates have been recently used for a number of active noise control applications. They are resistant to difficult environmental conditions including dust, humidity, and even precipitation. However, their properties significantly depend on temperature. The plate temperature changes, caused by ambient temperature changes or plate heating due to internal friction, result in varying response of the plate, and may make it significantly different than response of a fixed model. Such mismatch may deteriorate performance of an active noise control system or even lead to divergence of a model-based adaptation algorithm. In this paper effects of vibrating plate temperature variation on a feedforward adaptive active noise reduction system with the multichannel Filtered-reference LMS algorithm are examined. For that purpose, a thin aluminum plate is excited with multiple Macro-Fiber Composite actuators. The plate temperature is forced by a set of Peltier cells, what allows for both cooling and heating the plate. The noise is generated at one side of the plate, and a major part of it is transmitted through the plate. The goal of the control system is to reduce sound pressure level at a specified area on the other side of the plate. To guarantee successful operation of the control system in face of plate temperature variation, a gain-scheduling scheme is proposed to support the Filtered-reference LMS algorithm.
Go to article

Abstract

Active Noise Control (ANC) of noise transmitted through a vibrating plate causes many problems not observed in classical ANC using loudspeakers. They are mainly due to vibrations of a not ideally clamped plate and use of nonlinear actuators, like MFC patches. In case of noise transmission though a plate, nonlinerities exist in both primary and secondary paths. Existence of nonlinerities in the system may degrade performance of a linear feedforward control system usually used for ANC. The performance degradation is especially visible for simple deterministic noise, such as tonal noise, where very high reduction is expected. Linear feedforward systems in such cases are unable to cope with higher harmonics generated by the nonlinearities. Moreover, nonlinearities, if not properly tackled with, may cause divergence of an adaptive control system. In this paper a feedforward ANC system reducing sound transmitted through a vibrating plate is presented. The ANC system uses nonlinear control filters to suppress negative effects of nonlinearies in the system. Filtered-error LMS algorithm, found more suitable than usually used Filtered-reference LMS algorithm, is employed for updating parameters of the nonlinear filters. The control system is experimentally verified and obtained results are discussed.
Go to article

Abstract

Passive noise reduction means are commonly used to reduce noise in the industry but, unfortunately, their effectiveness is poor in the low frequency range. By applying active structural acoustic control to the enclosure walls significant improvement of the insulating properties in this frequency range can be achieved. In this paper a model of double panel structure with ASAC is presented. The structure consists of two aluminium plates separated by an air gap. Two inertial magnetoelectric actuators and two piezoceramic MFC sensors were used for controlling the structure. A multichannel FxLMS algorithm with virtual error microphone technique is used as a control algorithm. The signal of a virtual error microphone is extrapolated basing on signals from MFC sensors. Performance of this actively controlled structure for tonal signals at selected frequencies is presented in the article. During the study, a double panel structure was mounted on one wall of sound insulating enclosure located in an acoustic chamber. During the measurements local and global reduction of noise test signal was investigated.
Go to article

Abstract

The development of digital signal processors and the increase in their computing capabilities bring opportunities to employ algorithms with multiple variable parameters in active noise control systems. Of particular interest are the algorithms based on artificial neural networks. This paper presents an active noise control algorithm based on a neural network and a nonlinear input-output system identification model. The purpose of the algorithm is an active noise control system with a nonlinear primary path. The algorithm uses the NARMAX system identification model. The neural network employed in the proposed algorithm is a multilayer perceptron. The error backpropagation rule with adaptive learning rate is employed to update the weight of the neural network. The performance of the proposed algorithm has been tested by numerical simulations. Results for narrow-band input signals and nonlinear primary path are presented below.
Go to article

Abstract

This paper proposes an active noise control (ANC) application to attenuate siren noise for the patient lying inside ambulance with no sound proofing. From the point of cost effectiveness, a local ANC system based on feedforward scheme is considered. Further, to handle the limitation of limited Zone of Silence (ZoS), the ANC based on virtual sensing is explored. The simulations are done in MATLAB for the recorded ambulance siren noise signal. The results indicate that ANC can be an effective solution for creating a silent environment for the patient.
Go to article

Abstract

For many adaptive noise control systems the Filtered-Reference LMS, known as the FXLMS algorithm is used to update parameters of the control filter. Appropriate adjustment of the step size is then important to guarantee convergence of the algorithm, obtain small excess mean square error, and react with required rate to variation of plant properties or noise nonstationarity. There are several recipes presented in the literature, theoretically derived or of heuristic origin. This paper focuses on a modification of the FXLMS algorithm, were convergence is guaranteed by changing sign of the algorithm steps size, instead of using a model of the secondary path. A TakagiSugeno-Kang fuzzy inference system is proposed to evaluate both the sign and the magnitude of the step size. Simulation experiments are presented to validate the algorithm and compare it to the classical FXLMS algorithm in terms of convergence and noise reduction.
Go to article

Abstract

There are many industrial environments which are exposed to a high-level noise, sometimes much higher than the level of speech. Verbal communication is then practically unfeasible. In order to increase the speech intelligibility, appropriate speech enhancement algorithms can be used. It is impossible to filter off the noise completely from the acquired signal by using a conventional filter, because of two reasons. First, the speech and the noise frequency contents are overlapping. Second, the noise properties are subject to change. The adaptive realisation of the Wiener-based approach can be, however, applied. Two structures are possible. One is the line enhancer, where the predictive realisation of the Wiener approach is used. The benefit of using this structure it that it does not require additional apparatus. The second structure takes advantage of the high level of noise. Under such condition, placing another microphone, even close to the primary one, can provide a reference signal well correlated with the noise disturbing the speech and lacking the information about the speech. Then, the classical Wiener filter can be used, to produce an estimate of the noise based on the reference signal. That noise estimate can be then subtracted from the disturbed speech. Both algorithms are verified, based on the data obtained from the real industrial environment. For laboratory experiments the G. R. A. S. artificial head and two microphones, one at back side of an earplug and another at the mouth are used.
Go to article

Abstract

In the areas of acoustic research or applications that deal with not-precisely-known or variable conditions, a method of adaptation to the uncertainness or changes is usually necessary. When searching for an adaptation algorithm, it is hard to overlook the least mean squares (LMS) algorithm. Its simplicity, speed of computation, and robustness has won it a wide area of applications: from telecommunication, through acoustics and vibration, to seismology. The algorithm, however, still lacks a full theoretical analysis. This is probabely the cause of its main drawback: the need of a careful choice of the step size - which is the reason why so many variable step size flavors of the LMS algorithm has been developed. This paper contributes to both the above mentioned characteristics of the LMS algorithm. First, it shows a derivation of a new necessary condition for the LMS algorithm convergence. The condition, although weak, proved useful in developing a new variable step size LMS algorithm which appeared to be quite different from the algorithms known from the literature. Moreover, the algorithm proved to be effective in both simulations and laboratory experiments, covering two possible applications: adaptive line enhancement and active noise control.
Go to article

Abstract

The Least Mean Square (LMS) algorithm and its variants are currently the most frequently used adaptation algorithms; therefore, it is desirable to understand them thoroughly from both theoretical and practical points of view. One of the main aspects studied in the literature is the influence of the step size on stability or convergence of LMS-based algorithms. Different publications provide different stability upper bounds, but a lower bound is always set to zero. However, they are mostly based on statistical analysis. In this paper we show, by means of control theoretic analysis confirmed by simulations, that for the leaky LMS algorithm, a small negative step size is allowed. Moreover, the control theoretic approach alows to minimize the number of assumptions necessary to prove the new condition. Thus, although a positive step size is fully justified for practical applications since it reduces the mean-square error, knowledge about an allowed small negative step size is important from a cognitive point of view.
Go to article

This page uses 'cookies'. Learn more