Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 39
items per page: 25 50 75
Sort by:

Abstract

The analyzed heat accumulator is a key element in a hybrid heating system. In this paper, analytical and numerical models of the ceramic heat accumulator are presented.The accuracy of finite difference methods will be assessed by comparing the results with those obtained from the exact analytical solution.
Go to article

Abstract

The article addresses the issues falling within the scope of the economic analysis of a detached building’s heating system with a direct evaporation ground source heat pump installation. The paper was elaborated based on the data made available by the investment’s contractor and the investor. The paper provides data on the investment expenditures and utility cost, calculations of the installation payback, internal return rate and the current net value.
Go to article

Abstract

The paper presents the calculations for the failure conditions of the ORC (organic Rankine cycle) cycle in the electrical power system. It analyses the possible reasons of breakdown, such as the electrical power loss or the automatic safety valve failure. The micro-CHP (combined heat and power) system should have maintenance-free configuration, which means that the user does not have to be acquainted with all the details of the ORC system operation. However, the system should always be equipped with the safety control systems allowing for the immediate turn off of the ORC cycle in case of any failure. In case of emergency, the control system should take over the safety tasks and protect the micro-CHP system from damaging. Although, the control systems are able to respond quickly to the CHP system equipped with the inertial systems, the negative effects of failure are unavoidable and always remain for some time. Moreover, the paper presents the results of calculations determining the inertia for the micro-CHP system of the circulating ORC pump, heat removal pump (cooling condenser) and the heat supply pump in failure conditions.
Go to article

Abstract

In the paper a heating system with a vapour compressor heat pump and vertical U-tube ground heat exchanger for small residential house is considered. A mathematical model of the system: heated object - vapour compressor heat pump - ground heat exchanger is presented shortly. The system investigated is equipped, apart from the heat pump, with the additional conventional source of heat. The processes taking place in the analyzed system are of unsteady character. The model consists of three elements; the first containing the calculation model of the space to be heated, the second - the vertical U-tube ground heat exchanger with the adjoining area of the ground. The equations for the elements of vapour compressor heat pump form the third element of the general model. The period of one heating season is taken into consideration. The results of calculations for two variants of the ground heat exchanger are presented and compared. These results concern variable in time parameters at particular points of the system and energy consumption during the heating season. This paper presents the mutual influence of the ground heat exchanger subsystem, elements of vapour compressor heat pump and heated space.
Go to article

Abstract

Exergy analysis of low temperature geothermal heat plant with compressor and absorption heat pump was carried out. In these two concepts heat pumps are using geothermal water at 19.5°C with spontaneous outflow 24 m3/h as a heat source. The research compares exergy efficiency and exergy destruction of considered systems and its components as well. For the purpose of analysis, the heating system was divided into five components: geothermal heat exchanger, heat pump, heat distribution, heat exchanger and electricity production and transportation. For considered systems the primary exergy consumption from renewable and non-renewable sources was estimated. The analysis was carried out for heat network temperature at 50/40°C, and the quality regulation was assumed. The results of exergy analysis of the system with electrical and absorption heat pump show that exergy destruction during the whole heating season is lower for the system with electrical heat pump. The exergy efficiencies of total system are 12.8% and 11.2% for the system with electrical heat pump and absorption heat pump, respectively.
Go to article

Abstract

This paper presents the results of thermodynamic analyses of a system using a horizontal ground heat exchanger to cool a residential building in summer and heat it in the autumn-winter period. The main heating device is a vapour compression heat pump with the ground as the lower heat source. The aim of the analyses is to examine the impact of heat supply to the ground in the summer period, when the building is cooled, on the operation of the heating system equipped with a heat pump in the next heating season, including electricity consumption. The processes occurring in cooling and heating systems have an unsteady nature. The main results of the calculations are among others the time-dependent values of heat fluxes extracted from or transferred to the ground heat exchanger, the fluxes of heat generated by the heat pump and supplied to the heated building by an additional heat source, the parameters in characteristic points of the systems, the temperature distributions in the ground and the driving electricity consumption in the period under analysis. The paper presents results of analysis of cumulative primary energy consumption of the analyzed systems and cumulative emissions of harmful substances. Słowa kluczowe
Go to article

Abstract

The article presents a numerical model of the concrete heat accumulator for solar heating systems. Model uses control volume finite element method with an explicit solution method for time integration. The use of an explicit method is an essential advantage in the simulation of time-dependent changes in temperature of the air at the accumulator inlet. The study compares the results of numerical model calculations of the accumulator heating with experimental measurements and with computational fluid dynamics modeling. The comparison shows a good correlation between the results of calculation using the model and the results of measurements.
Go to article

Abstract

Knowledge of the temperature distribution in subsurface layers of the ground is important in the design, modelling and exploitation of ground heat exchangers. In this work a mathematical model of heat transfer in the ground is presented. The model is based on the solution of the equation of transient heat transfer in a semi-infinite medium. In the boundary condition on the surface of the ground radiation fluxes (short- and long-wave), convective heat flux and evaporative heat flux are taken into account. Based on the developed model, calculations were carried out to determine the impact of climatic conditions and the physical properties of the ground on the parameters of the Carslaw-Jeager equation. Example results of calculated yearly courses of the daily average temperature of the surface of the ground and the amount of particular heat fluxes on the ground surface are presented. The compatibility of ground temperature measurements at different depths with the results obtained from the Carslaw–Jaeger equation is evaluated. It was found that the temperature distribution in the ground and its variability in time can be calculated with good accuracy.
Go to article

Abstract

The paper presents an experimental investigation of a silicone based heat exchanger, with passive heat transfer intensification by means of surface enhancement. The main objective of this paper was to experimentally investigate the performance of a heat exchanger module with the enhanced surface. Heat transfer in the test section has been examined and described with precise measurements of thermal and flow conditions. Reported tests were conducted under steady-state conditions for single-phase liquid cooling. Proposed surface modification increases heat flux by over 60%. Gathered data presented, along with analytical solutions and numerical simulation allow the rational design of heat transfer devices.
Go to article

Abstract

In this paper, effects of non-Fourier thermal wave interactions in a thin film have been investigated. The non-Fourier, hyperbolic heat conduction equation is solved, using finite difference method with an implicit scheme. Calculations have been carried out for three geometrical configurations with various film thicknesses. The boundary condition of a symmetrical temperature step-change on both sides has been used. Time history for the temperature distribution for each investigated case is presented. Processes of thermal wave propagation, temperature peak build-up and reverse wave front creation have been described. It has been shown that (i) significant temperature overshoot can appear in the film subjected to symmetric thermal load (which can be potentially dangerous for reallife application), and (ii) effect of temperature amplification decreases with increased film thickness.
Go to article

Abstract

Work on increasing the efficiency of heat exchangers used in car air conditioning systems may lead to a partial change in the construction of refrigeration systems. One of such changes is the use of smaller gas coolers, which directly translates into a reduction in the production costs of the entire system. The article presents the use of computational fluid dynamics methods to simulate the impact of changing the shape of an internal heat exchanger on the cooling efficiency with R744 as the refrigerant. Internal heat exchangers with different geometry of the outer channels were subjected to numerical analysis. The obtained results of calculations show temperature changes in inner and outer channels on the length of the heat exchanger.
Go to article

Abstract

The purpose of this article was to discuss the use of adsorption chillers for waste heat recovery. The introduction discusses the need to undertake broader measures for the effective management of waste heat in the industry and discusses the benefits and technical problems related to heat recovery in industrial plants. In addition, heat sources for adsorption chillers and their application examples were described. The principle of operation of adsorption chillers is explained in the next chapter. Heat sources for adsorption chillers are indicated and their application examples are described. The above considerations have allowed the benefits and technical obstacles related to the use of adsorption chillers to be highlighted. The currently used adsorbents and adsorbates are discussed later in the article. The main part of the paper discusses the use of adsorption chillers for waste heat management in the glassworks. The calculations assumed the natural gas demand of 20.1 million m3 per year and the electricity demand of 20,000 MWh/year. As a result of conducted calculations, a 231 kW adsorption chiller, ensuring the annual cold production of 2,021 MWh, was selected. The economic analysis of the proposed solution has shown that the investment in the adsorption chiller supplied with waste heat from the heat recovery system will bring significant economic benefits after 10 years from its implementation, even with total investment costs of PLN 1,900,000. However, it was noted that in order to obtain satisfactory economic results the production must meet the demand while the cost of building a heat recovery system shall not exceed PLN 1 million.
Go to article

Abstract

The application of waste heat from exhaust gas of ship’s main engines has become widely practiced as early as in the 1930s. Thus the increase of ship’s overall efficiency was improved. Nowadays all newly built ships of the 400 gross tonnage and above must have specified energy efficiency design index, which is a measure for CO2 emissions of the ship and its impact on the environment. Therefore, the design of waste heat recovery systems requires special attention. The use of these systems is one of the basic ways to reduce CO2 emissions and to improve the ship’s energy efficiency. The paper describes the ship’s heating systems designed for the use of waste heat contained in the exhaust gas of self-ignition engines, in which the heat carriers are respectively water vapor, water or thermal oil. Selected results of comparative exergy analysis of simplified steam, water and oil heating systems have been presented. The results indicate that the oil heating system is comparable to the water system in terms of internal exergy losses. However, larger losses of exergy occur in the case of a steam system. In the steam system, a significant loss is caused by the need to cool the condensate to avoid cavitation in boiler feed pumps. This loss can in many cases cause the negative heat balance of ship during sea voyage while using only the exhaust gas boilers.
Go to article

Abstract

The paper presents the results of optimizing the coefficient of the share of cogeneration expressed by an empirical formula dedicated to designers, which will allow to determine the optimal value of the share of cogeneration in contemporary cogeneration systems with the thermal storages feeding the district heating systems. This formula bases on the algorithm of the choice of the optimal coefficient of the share of cogeneration in district heating systems with the thermal storage, taking into account additional benefits concerning the promotion of high-efficiency cogeneration and the decrease of the cost of CO2 emission thanks to cogeneration. The approach presented in this paper may be applicable both in combined heat and power (CHP) plants with back-pressure turbines and extraction-condensing turbines.
Go to article

Abstract

The article analyzes the risk factors related to the energy use of alternative fuels from waste. The essence of risk and its impact on economic activity in the area of waste management were discussed. Then, a risk assessment, on the example of waste fractions used for the production of alternative fuel, was carried out. In addition, the benefits for the society and the environment from the processing of alternative fuels for energy purposes, including, among others: reducing the cost of waste disposal, limiting the negative impact on water, soil and air, reducing the amount of waste deposited, acquisition of land; reduction of the greenhouse effect, facilitating the recycling of other fractions, recovery of electricity and heat, and saving conventional energy carriers, were determined. The analysis of risk factors is carried out separately for plants processing waste for alternative fuel production and plants producing energy from this type of fuel. Waste processing plants should pay attention to investment, market (price, interest rate, and currency), business climate, political, and legal risks, as well as weather, seasonal, logistic, technological, and loss of profitability or bankruptcy risks. Similar risks are observed in the case of energy companies, as they operate in the same external environment. Moreover, internal risks may be similar; however, the specific nature of the operation of each enterprise should be taken into account. Energy companies should pay particular attention to the various types of costs that may threaten the stability of operation, especially in the case of regulated energy prices. The risk associated with the inadequate quality of the supplied and stored fuels is important. This risk may disrupt the technological process and reduce the plant’s operational efficiency. Heating plants and combined heat and power plants should also not underestimate the non-catastrophic weather risk, which may lead to a decrease in heat demand and a reduction in business revenues. A comprehensive approach to risk should protect enterprises against possible losses due to various types of threats, including both external and internal threats.
Go to article

Abstract

An attempt was made to determine the vertical momentum and heat exchange in the near-ground atmosphere layer in the specific conditions of a sub-Antarctic island. For this purpose, some of the results of the measurements of temperature and wind speed carried out at the levels 10, 2, 0.5 and 0.05 m, during the IVth Antarctic Expedition of the Polish Academy of Sciences in March 1980, were used. The vertical gradients of the two elements and the wind stress and the heat flux in the layers under study, were calculated.
Go to article

Abstract

On the basis of the results of direct measurements, the conduction properties of the yearly behaviour of the halt flux conducted in the tundra soil (S) are determined. In general, the cooling period of the soil profile lasted from August to January, with highest intensity in October (S = —4.8 Wm-2). A rapid intensification of the heat exchange in the soil occurred in July (S = 7.4 Wm-2 ) . The 24-hour values of S were found to vary greatly (from 19 Wm-2 to 32 Wm-2). For chosen days, relationships were determined among the particular elements of the heat balance of the active layer.
Go to article

Abstract

Research in Hornsund (SW Spitsbergen) aimed to determine time distribution of heat flux in various soils of Arctic periglacial zone in spring and summer. Typical soils were analysed: tundra gleyey cryogenic soil (Pergelic Cryaquent), tundra peaty soil (Pergelic Histosot) and arctic desert soil (Pergelic Cryorthent). Research sites were located in low plains not covered with ice, near a sea, at 7—13 m a.s.l. Heat flux in soils was measured and recorded automatically every 60 s throughout a whole observation period and concurrently at three sites. In spring and summer intensive heat accumulation was observed in all examined soils. Independently on the weather, a cryogenic gleyey soil received greatest heat throughout a day. Environmental conditions have distinct influence on heat resources in soils.
Go to article

Abstract

One of the parameters which enables the evaluation of carbonaceous material is the thermal effect of wetting. The value of the heat of wetting provides information about the surface energy and the texture of the materials immersed in the wetting liquid. Knowledge of the heat of wetting of the carbonaceous materials is used to research their sorption properties, to characterize the structure and to determine the surface area. A method of me asuring the wetting of the carbonaceous materials as one of the methods to evaluate the carbonaceous materials was proposed. On the basis of research which was conducted, one determined the heat of wetting black coal from the Brzeszcze mine by methyl alcohol and lignites from the Turów and Bełchatów mine. One of activated carbons furnished by the Gryfskand company (WD-extra) was selected for the purpose of the comparison. The enthalpy of immersion was calculated on the basis of the results, the surface of the carbonaceous materials that were studied. It was revealed that the energetic effects of wetting depend both upon the microporous structure and the chemical nature of the adsorbent. The greatest heat of wetting calculated per 1g of the carbonaceous material, which has the most developed surface area and micropore volume, was obtained for the activated carbon. However, the heat of wetting does not increase proportionally to the surface area. The study revealed that the thermal effects of wetting for fossil coal decreases with the increasing of the surface area. The linear relationship was obtained for the three samples which were studied. The highest thermal effects (ΔT) and heat of wetting (Q) among the fossil coals was determined for the lignite from the Bełchatów mine, even though this coal had the least-developed porous structure. One may discern a clear influence of the swelling process upon the measured thermal effects on the basis of this sample.
Go to article

Abstract

Microbes living in the polar regions have some common and unique strategies to respond to thermal stress. Nevertheless, the amount of information available, especially at the molecular level is lacking for some organisms such as Antarctic psychrophilic yeast. For instance, it is not known whether molecular chaperones in Antarctic yeasts play similar roles to those from mesophilic yeasts when they are exposed to heat stress. Therefore, this project aimed to determine the gene expression patterns and roles of molecular chaperones in Antarctic psychrophilic Glaciozyma antarctica PI12 that was exposed to heat stress. G. antarctica PI12 was grown at its optimal growth temperature of 12ºC and later exposed to heat stresses at 16ºC and 20ºC for 6 hours. Transcriptomes of those cells were extracted, sequenced and analyzed. Thirty-three molecular chaperone genes demonstrated differential expression of which 23 were up-regulated while 10 were down-regulated. Functions of up-regulated molecular chaperone genes were related to protein binding, response to a stimulus, chaperone binding, cellular response to stress, oxidation, and reduction, ATP binding, DNA-damage response and regulation for cellular protein metabolic process. On the other hand, functions of down-regulated molecular chaperone genes were related to chaperone-mediated protein complex assembly, transcription, cellular macromolecule metabolic process, regulation of cell growth and ribosome biogenesis. The findings provided information on how molecular chaperones work together in a complex network to protect the cells under heat stress. It also highlights the evolutionary conserved protective role of molecular chaperones in psychrophilic yeast, G. antarctica, and mesophilic yeast, Saccharomyces cerevisiae.
Go to article

Abstract

The progressive processes of globalization and changes in the global, European and local economy require integrated efforts aimed at solving problems related to development at the national regional and the local level involving the environment, energy sources, climate and technological transformation issues. European Union Member States are given right to create an individual Energy mix. Coal will continue to play a major role in Poland’s energy mix during the next decades. Polish coal reserves can provide energy security for decades. Despite crude oil and natural gas growth in fuel consumption, coal will continue to be the stabilizer of energy security for the country and play an important role in Poland’s energy mix in the years to come. However, further coal consumption requires investments in low carbon technologies which are of high efficiency and in high-efficiency cogeneration. The validity of the full utilization of cogeneration potential should be highlighted. Operating cogeneration plants are more expensive than power plants but they are more efficient and generate less carbon emissions. In accordance with the assumptions of the Energy policy of Poland, a low-carbon economy with renewable Energy sources and nuclear Energy should be supported and developed, however the obsolete coal generators should be replaced with low-carbon high-efficient ones.
Go to article

Abstract

The policy of sustainable development seeks to improve energy efficiency of industrial equipment. Efforts to improve energy efficiency also apply to the paint shops, where the recovery of waste heat is sought. The main source of a large amount of low-temperature waste heat in the paint shop is the spray booth. The second place where a large amount of low temperature waste heat is released is the room where the compressed air is prepared. Low energy efficiency of air compressors requires a large electric power supply. As a result, the emitted large heat fluxes become waste energy of the technological process. Heat is equivalent to up to 93% of the electric power supplied in the air compression process. There are solutions for recovering heat from compressors coming from the oil cooling water, but then the waste heat from the cooling of the compressed air and from the electric motor is released into air in the room. A method for recovering low-temperature waste heat from the air preparation room by means of an air-source heat pump has been proposed. An energy balance of the air compression and dehumidification process for the paint shop was made. A Matlab’s built-in numerical model includes air compressor and dehumidifier, heat recovery and accumulation for the purposes of use in the spray booth. A simulation experiment was carried out on the effectiveness of heat recovery from the air preparation room. The use of combined energy management in paint shops was proposed.
Go to article

Abstract

Excitation of the entropy mode in the field of intense sound, that is, acoustic heating, is theoretically considered in this work. The dynamic equation for an excess density which specifies the entropy mode, has been obtained by means of the method of projections. It takes the form of the diffusion equation with an acoustic driving force which is quadratically nonlinear in the leading order. The diffusion coefficient is proportional to the thermal conduction, and the acoustic force is proportional to the total attenuation. Theoretical description of instantaneous heating allows to take into account aperiodic and impulsive sounds. Acoustic heating in a half-space and in a planar resonator is discussed. The aim of this study is to evaluate acoustic heating and determine the contribution of thermal conduction and mechanical viscosity in different boundary problems. The conclusions are drawn for the Dirichlet and Neumann boundary conditions. The instantaneous dynamic equation for variations in temperature, which specifies the entropy mode, is solved analytically for some types of acoustic exciters. The results show variation in temperature as a function of time and distance from the boundary for different boundary conditions.
Go to article

Abstract

Maintaining railway turnout operability is crucial for ensuring railway transport safety. Electric heating of railway turnouts is a significant technical and economic issue. The classical heating is characterised by high power consumption. For this reason, research is needed to optimise the current system. This paper presents results of a numerical analysis and of experimental researches. The numerical analysis was carried out using the ANSYS software. There was conducted a numerical comparative analysis of energy loss during heating performed using two different heaters. Including the classical method and a heater thermally insulated from a rail. In the first step, heating of a working space filled with a substitute snow model was considered. The snow-covered surface area was held within the working space of the turnout. It was assumed that the snow substitute material had thermal properties approximately the same as real light snow. It was also assumed that the material is in the solid state which would not undergo a phase change. In the next step, a real snow model that included the phase change process was taken into account. The energy efficiency and heat distribution in the turnout have been analysed and compared. The experimental researches were carried out in a physical model. The results showed that the use of a contactless heater results in creating a larger area over which emitted heat affected snow in the working space. Consequently, more snow was melted around the contactless heater than the classic one. This experimental observation supported the results of the numerical analyses presented previously.
Go to article

Abstract

Coal is a naturally occurring solid fuel used, among others, for heating and for electricity production. Despite the development of the gas and heating network in our country, as well as the growing interest in the use of renewable energy sources, it still remains the most frequent fuel burned in local sources for the production of thermal energy. The article describes actual heating coal demand in the municipal and residential sector, with the distinction of different assortments, depending on the solid fuel heating source applied. Moreover, a subjective list of factors that have a key impact on the change in heating coal demand for this market was presented, taking the regulatory environment, global trends in housing heating and statistical surveys on the preferences for individual heat sources replacement into account. The confrontation of observed phenomena allowed for possible scenarios of changes in the demand for heating coal with the prospect until 2030, broken down into its individual assortments to be elaborated.
Go to article

This page uses 'cookies'. Learn more